Sign In | Join Free | My himfr.com
Home > PLC SIMATIC S7-1500 >

OEM CPU 1500 Siemens 6ES7514-2SN03-0AB0 BusAdapters

    Buy cheap OEM CPU 1500 Siemens 6ES7514-2SN03-0AB0 BusAdapters from wholesalers
     
    Buy cheap OEM CPU 1500 Siemens 6ES7514-2SN03-0AB0 BusAdapters from wholesalers
    • Buy cheap OEM CPU 1500 Siemens 6ES7514-2SN03-0AB0 BusAdapters from wholesalers

    OEM CPU 1500 Siemens 6ES7514-2SN03-0AB0 BusAdapters

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 6ES7514-2SN03-0AB0
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 100
    Delivery Time : 10-12Days
    • Product Details
    • Company Profile

    OEM CPU 1500 Siemens 6ES7514-2SN03-0AB0 BusAdapters

    SIEMENS 6ES7514-2SN03-0AB0 CARD REQUIRED, BUSADAPTER REQUIRED FOR 1ST INTERFACE **** APPROVALS AND CERTIFICATES ACCORDIN

    Okay, got it. The details you provided are for the SIEMENS 6ES7514-2SN03-0AB0 SIMATIC S7-1500 CPU module:

    Product Description:
    - The 6ES7514-2SN03-0AB0 is a SIMATIC S7-1500 CPU module.
    - It requires a SIMATIC memory card for program storage and additional functionality.
    - A busadapter is required for the module's 1st interface.

    Key Features:
    - SIMATIC S7-1500 CPU module with specific processing capabilities.
    - Requires a SIMATIC memory card for program storage, firmware updates, and other advanced features.
    - Supports the use of a busadapter for the module's 1st communication interface.

    Connectivity:
    - The module has at least 1 communication interface (1st interface) that requires a busadapter for connectivity.
    - The busadapter enables the use of various communication protocols and fieldbus systems, such as PROFINET, PROFIBUS, or other industrial Ethernet standards.

    SIMATIC Memory Card:
    - The 6ES7514-2SN03-0AB0 module requires a SIMATIC memory card for program storage, firmware updates, and additional functionality.
    - The memory card provides the necessary storage capacity and enables advanced features of the CPU module.

    Busadapter:
    - A busadapter is required for the module's 1st communication interface.
    - The busadapter allows the CPU module to connect to and communicate over different industrial communication networks and fieldbuses.

    Approvals and Certifications:
    - As a SIMATIC S7-1500 CPU module, the 6ES7514-2SN03-0AB0 likely has relevant industrial certifications and approvals, such as:
    - IEC 61131-2 (Programmable controllers)
    - IEC 61784-2 (PROFINET)
    - UL Recognized Component marking
    - Hazardous Locations approvals (e.g., Class I, Division 2)
    - Marine classification society approvals (e.g., DNV GL, ABS, LR, etc.)
    - Any other relevant industry-specific certifications and standards required for the intended application and geography.

    Please let me know if I have accurately summarized the key details of the SIEMENS 6ES7514-2SN03-0AB0 SIMATIC S7-1500 CPU module, including the required approvals and certifications.

    General information
    Product type designationCPU 1514SP F-2 PN
    HW functional statusFS01
    Firmware versionV3.0
    ● FW update possibleYes
    Product function
    ● I&M dataYes; I&M0 to I&M3
    ● Module swapping during operation (hot swapping)Yes; Multi-hot swapping
    ● Isochronous modeYes; only with PROFINET; with minimum OB 6x cycle of 375 µs
    Engineering with
    ● STEP 7 TIA Portal configurable/integrated from versionV18 (FW V3.0)
    Configuration control
    via datasetYes
    Control elements
    Mode selector switch1
    Supply voltage
    Rated value (DC)24 V
    permissible range, lower limit (DC)19.2 V
    permissible range, upper limit (DC)28.8 V
    Reverse polarity protectionYes
    Mains buffering
    ● Mains/voltage failure stored energy time10 ms
    Input current
    Current consumption (rated value)0.51 A
    Current consumption, max.0.7 A
    Inrush current, max.1.34 A; Rated value
    I²t0.3 A²·s
    Power
    Infeed power to the backplane bus8.05 W
    Power loss
    Power loss, typ.3.5 W
    Memory
    Number of slots for SIMATIC memory card1
    SIMATIC memory card requiredYes
    Work memory
    ● integrated (for program)900 kbyte
    ● integrated (for data)3.5 Mbyte
    Load memory
    ● Plug-in (SIMATIC Memory Card), max.32 Gbyte
    Backup
    ● maintenance-freeYes
    CPU processing times
    for bit operations, typ.6 ns
    for word operations, typ.7 ns
    for fixed point arithmetic, typ.9 ns
    for floating point arithmetic, typ.37 ns
    CPU-blocks
    Number of elements (total)8 000; Blocks (OB, FB, FC, DB) and UDTs
    DB
    ● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
    ● Size, max.3.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
    FB
    ● Number range0 ... 65 535
    ● Size, max.900 kbyte
    FC
    ● Number range0 ... 65 535
    ● Size, max.900 kbyte
    OB
    ● Size, max.900 kbyte
    ● Number of free cycle OBs100
    ● Number of time alarm OBs20
    ● Number of delay alarm OBs20
    ● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 250 µs
    ● Number of process alarm OBs50
    ● Number of DPV1 alarm OBs3
    ● Number of isochronous mode OBs1
    ● Number of technology synchronous alarm OBs2
    ● Number of startup OBs100
    ● Number of asynchronous error OBs4
    ● Number of synchronous error OBs2
    ● Number of diagnostic alarm OBs1
    Nesting depth
    ● per priority class24; Up to 8 possible for F-blocks
    Counters, timers and their retentivity
    S7 counter
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC counter
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    S7 times
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC timer
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max.512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
    Flag
    ● Size, max.16 kbyte
    ● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
    Data blocks
    ● Retentivity adjustableYes
    ● Retentivity presetNo
    Local data
    ● per priority class, max.64 kbyte; max. 16 KB per block
    Address area
    Number of IO modules8 192; max. number of modules / submodules
    I/O address area
    ● Inputs32 kbyte; All inputs are in the process image
    ● Outputs32 kbyte; All outputs are in the process image
    per integrated IO subsystem
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    per CM/CP
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    Subprocess images
    ● Number of subprocess images, max.32
    Address space per module
    ● Address space per module, max.288 byte; For input and output data respectively
    Address space per station
    ● Address space per station, max.2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules
    Hardware configuration
    Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
    Number of DP masters
    ● Via CM1
    Number of IO Controllers
    ● integrated2
    ● Via CM0
    Rack
    ● Modules per rack, max.80; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
    ● Quantity of operable ET 200SP modules, max.64
    ● Quantity of operable ET 200AL modules, max.16
    PtP CM
    ● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
    Time of day
    Clock
    ● TypeHardware clock
    ● Backup time6 wk; At 40 °C ambient temperature, typically
    ● Deviation per day, max.10 s; Typ.: 2 s
    Operating hours counter
    ● Number16
    Clock synchronization
    ● supportedYes
    ● to DP, masterYes; Via CM DP module
    ● to DP, slaveYes; Via CM DP module
    ● in AS, masterYes
    ● in AS, slaveYes
    ● on Ethernet via NTPYes
    Interfaces
    Number of PROFINET interfaces2
    Number of PROFIBUS interfaces1; Via CM DP module
    Optical interfaceNo
    1. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X1 P1 and X1 P2 via BusAdapter BA 2x RJ45
    ● Number of ports2; via BusAdapter
    ● integrated switchYes
    ● BusAdapter (PROFINET)Yes; compatible BusAdapters: BA 2x RJ45, BA 2x FC, BA 2x M12
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyYes
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeYes
    — Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
    — IRTYes
    — PROFIenergyYes; per user program
    — Prioritized startupYes; Max. 32 PROFINET devices
    — Number of connectable IO Devices, max.256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Of which IO devices with IRT, max.64
    — Number of connectable IO Devices for RT, max.256
    — of which in line, max.256
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for IRT
    — for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive
    — for send cycle of 500 µs500 µs to 8 ms
    — for send cycle of 1 ms1 ms to 16 ms
    — for send cycle of 2 ms2 ms to 32 ms
    — for send cycle of 4 ms4 ms to 64 ms
    — With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
    Update time for RT
    — for send cycle of 250 µs250 µs to 128 ms
    — for send cycle of 500 µs500 µs to 256 ms
    — for send cycle of 1 ms1 ms to 512 ms
    — for send cycle of 2 ms2 ms to 512 ms
    — for send cycle of 4 ms4 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTYes
    — PROFIenergyYes; per user program
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — activation/deactivation of I-devicesYes; per user program
    — Asset management recordYes; per user program
    2. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X2
    ● Number of ports1
    ● integrated switchNo
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyNo
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — Direct data exchangeNo
    — IRTNo
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Number of connectable IO Devices, max.32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Number of connectable IO Devices for RT, max.32
    — of which in line, max.32
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for RT
    — for send cycle of 1 ms1 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTNo
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — activation/deactivation of I-devicesYes; per user program
    — Asset management recordYes; per user program
    3. Interface
    Interface types
    ● RS 485Yes; Via CM DP module
    ● Number of ports1
    Protocols
    ● PROFIBUS DP masterYes
    ● PROFIBUS DP slaveYes
    ● SIMATIC communicationYes
    PROFIBUS DP master
    ● Number of connections, max.48; Of which 4 each reserved for ES and HMI
    ● Number of DP slaves, max.125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    Services
    — PG/OP communicationYes
    — EquidistanceNo
    — Isochronous modeNo
    — Activation/deactivation of DP slavesYes

    OEM CPU 1500 Siemens 6ES7514-2SN03-0AB0 BusAdapters

    Quality OEM CPU 1500 Siemens 6ES7514-2SN03-0AB0 BusAdapters for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Voboal Industrial Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)