    SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 6ES7412-1XJ05-0AB0
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 10PS
    Delivery Time : 5-10DAYS
    • Product Details
    • Company Profile

    SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1


    Product Name: SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1


    Introduction:

    The SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1 is a powerful programmable logic controller designed for large and complex automation applications. It is part of the SIEMENS SIMATIC S7-400 series, which offers high-performance control and communication capabilities for demanding industrial environments.


    Origin: Germany


    Product Specifications:

    - Product Name: SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1

    - CPU Type: 412-1

    - Compatibility: SIEMENS SIMATIC S7-400 series

    - Number of Digital Inputs: Varies depending on configuration

    - Number of Digital Outputs: Varies depending on configuration

    - Number of Analog Inputs: Varies depending on configuration

    - Number of Analog Outputs: Varies depending on configuration

    - Communication Ports: Multiple communication interfaces (e.g., Ethernet, PROFIBUS, MPI)

    - Memory: Varies depending on configuration

    - Operating Temperature: 0 to 60°C

    - Dimensions (W x H x D): Varies depending on the module

    - Weight: Varies depending on the module


    Product Features:

    - High-performance CPU for large and complex automation applications

    - Compatible with the SIEMENS SIMATIC S7-400 series

    - Supports a wide range of digital and analog inputs and outputs

    - Multiple communication interfaces for seamless integration into industrial networks

    - Flexible memory configuration to accommodate specific application requirements

    - Robust construction and reliable performance for demanding industrial environments

    - Easy programming and configuration using the STEP 7 programming software


    Functionality:

    - The SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1 is designed to provide high-performance control and communication capabilities for large and complex automation applications.

    - It is compatible with the SIEMENS SIMATIC S7-400 series, allowing for seamless integration with other modules and components.

    - The CPU supports a wide range of digital and analog inputs and outputs, providing flexibility for various automation requirements.

    - Multiple communication interfaces (such as Ethernet, PROFIBUS, and MPI) enable easy connectivity to other devices and networks.

    - The memory configuration can be customized to accommodate specific application requirements.

    - With its robust construction and reliable performance, the CPU is suitable for demanding industrial environments.

    - Programming and configuration can be done using the STEP 7 programming software, which offers a user-friendly interface for efficient development and maintenance.


    Please note that for more detailed technical specifications and information, it is recommended to refer to the official documentation or contact Siemens directly.


    SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1


    ********** Replacement part ********* SIMATIC S7-400, CPU 412-1 Central processing unit with: work memory 288 KB, (144 KB code, 144 KB of data), Interface MPI/DP 12 Mbit/s,
    General information
    Product type designationCPU 412-1
    HW functional status03
    Firmware versionV5.3
    Product function
    ● Isochronous modeYes; For PROFIBUS only
    Engineering with
    ● Programming packageSTEP 7 V5.3 SP2 or higher with HW update
    CiR - Configuration in RUN
    CiR synchronization time, basic load100 ms
    CiR synchronization time, time per I/O byte30 µs
    Supply voltage
    Rated value (DC)Power supply via system power supply
    Input current
    from backplane bus 5 V DC, typ.0.5 A
    from backplane bus 5 V DC, max.0.6 A
    from backplane bus 24 V DC, max.150 mA; 150 mA per DP interface
    from interface 5 V DC, max.90 mA
    Power loss
    Power loss, typ.2.5 W
    Power loss, max.3 W
    Memory
    Type of memoryRAM
    Work memory
    ● integrated288 kbyte
    ● integrated (for program)144 kbyte
    ● integrated (for data)144 kbyte
    ● expandableNo
    Load memory
    ● expandable FEPROMYes; with Memory Card (FLASH)
    ● expandable FEPROM, max.64 Mbyte
    ● integrated RAM, max.512 kbyte
    ● expandable RAMYes; with Memory Card (RAM)
    ● expandable RAM, max.64 Mbyte
    Backup
    ● presentYes
    ● with batteryYes; all data
    ● without batteryNo
    Battery
    Backup battery
    ● Backup current, typ.125 µA; up to 40 °C
    ● Backup current, max.300 µA
    ● Backup time, max.See reference manual, module data, Chapter 3.3
    ● Feeding of external backup voltage to CPU5 V DC to 15 V DC
    CPU processing times
    for bit operations, typ.75 ns
    for word operations, typ.75 ns
    for fixed point arithmetic, typ.75 ns
    for floating point arithmetic, typ.225 ns
    CPU-blocks
    DB
    ● Number, max.1 500; Number range: 1 to 16000
    ● Size, max.64 kbyte
    FB
    ● Number, max.750; Number range: 0 to 7999
    ● Size, max.64 kbyte
    FC
    ● Number, max.750; Number range: 0 to 7999
    ● Size, max.64 kbyte
    OB
    ● Number, max.see instruction list
    ● Size, max.64 kbyte
    ● Number of free cycle OBs1; OB 1
    ● Number of time alarm OBs2; OB 10, 11
    ● Number of delay alarm OBs2; OB 20, 21
    ● Number of cyclic interrupt OBs2; OB 32, 35 (shortest cycle that can be set = 500 µs)
    ● Number of process alarm OBs2; OB 40, 41
    ● Number of DPV1 alarm OBs3; OB 55-57
    ● Number of isochronous mode OBs2; OB 61-62
    ● Number of multicomputing OBs1; OB 60
    ● Number of background OBs1; OB 90
    ● Number of startup OBs3; OB 100-102
    ● Number of asynchronous error OBs9; OB 80-88
    ● Number of synchronous error OBs2; OB 121, 122
    Nesting depth
    ● per priority class24
    ● additional within an error OB1
    Counters, timers and their retentivity
    S7 counter
    ● Number2 048
    Retentivity
    — adjustableYes
    — presetZ 0 to Z 7
    Counting range
    — lower limit0
    — upper limit999
    IEC counter
    ● presentYes
    ● TypeSFB
    ● NumberUnlimited (limited only by RAM capacity)
    S7 times
    ● Number2 048
    Retentivity
    — adjustableYes
    — presetNo times retentive
    Time range
    — lower limit10 ms
    — upper limit9 990 s
    IEC timer
    ● presentYes
    ● TypeSFB
    ● NumberUnlimited (limited only by RAM capacity)
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max.Total working and load memory (with backup battery)
    Flag
    ● Size, max.4 kbyte; Size of bit memory address area
    ● Retentivity availableYes
    ● Retentivity presetMB 0 to MB 15
    ● Number of clock memories8; in 1 memory byte
    Local data
    ● adjustable, max.8 kbyte
    ● preset4 kbyte
    Address area
    I/O address area
    ● Inputs4 kbyte
    ● Outputs4 kbyte
    Process image
    ● Inputs, adjustable4 kbyte
    ● Outputs, adjustable4 kbyte
    ● Inputs, default128 byte
    ● Outputs, default128 byte
    ● consistent data, max.244 byte
    ● Access to consistent data in process imageYes
    Subprocess images
    ● Number of subprocess images, max.15
    Digital channels
    ● Inputs32 768
    — of which central32 768
    ● Outputs32 768
    — of which central32 768
    Analog channels
    ● Inputs2 048
    — of which central2 048
    ● Outputs2 048
    — of which central2 048
    Hardware configuration
    Integrated power supplyNo
    Number of expansion units, max.21
    connectable OPs31
    MulticomputingYes; 4 CPUs max. (with UR1 or UR2)
    Interface modules
    ● Number of connectable IMs (total), max.6
    ● Number of connectable IM 460s, max.6
    ● Number of connectable IM 463s, max.4; IM 463-2
    Number of DP masters
    ● integrated1
    ● via CP10; CP 443-5 Extended
    ● via IM 4674
    ● Mixed mode IM + CP permittedNo; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
    ● via interface module0
    ● Number of pluggable S5 modules (via adapter capsule in central device), max.6
    Number of IO Controllers
    ● integrated0
    ● via CP4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
    Number of operable FMs and CPs (recommended)
    ● FMLimited by number of slots and number of connections
    ● CP, PtPCP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections
    ● PROFIBUS and Ethernet CPs14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum
    Slots
    ● required slots1
    Time of day
    Clock
    ● Hardware clock (real-time)Yes
    ● retentive and synchronizableYes
    ● Resolution1 ms
    ● Deviation per day (buffered), max.1.7 s; Power off
    ● Deviation per day (unbuffered), max.8.6 s; For power On
    Operating hours counter
    ● Number16
    ● Number/Number range0 to 15
    ● Range of valuesSFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
    ● Granularity1 h
    ● retentiveYes
    Clock synchronization
    ● supportedYes
    ● to MPI, masterYes
    ● to MPI, slaveYes
    ● to DP, masterYes
    ● to DP, slaveYes
    ● in AS, masterYes
    ● in AS, slaveYes
    ● on Ethernet via NTPNo; Via CP
    ● to IF 964 DPNo
    Time difference in system when synchronizing via
    ● MPI, max.200 ms
    Interfaces
    Interfaces/bus type1 x MPI/PROFIBUS DP
    Number of RS 485 interfaces1; Combined MPI / PROFIBUS DP
    Optical interfaceNo
    1. Interface
    Interface typeMPI/PROFIBUS DP
    IsolatedYes
    Interface types
    ● RS 485Yes
    ● Output current of the interface, max.150 mA
    Protocols
    ● MPIYes
    ● PROFIBUS DP masterYes
    ● PROFIBUS DP slaveYes
    MPI
    ● Number of connections32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
    ● Transmission rate, max.12 Mbit/s
    Services
    — PG/OP communicationYes
    — RoutingYes
    — Global data communicationYes
    — S7 basic communicationYes
    — S7 communicationYes
    — S7 communication, as clientYes
    — S7 communication, as serverYes
    PROFIBUS DP master
    ● Number of connections, max.16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
    ● Transmission rate, max.12 Mbit/s
    ● Number of DP slaves, max.32
    Services
    — PG/OP communicationYes
    — RoutingYes; S7 routing
    — Global data communicationNo
    — S7 basic communicationYes
    — S7 communicationYes
    — S7 communication, as clientYes
    — S7 communication, as serverYes
    — EquidistanceYes
    — Isochronous modeYes
    — SYNC/FREEZEYes
    — Activation/deactivation of DP slavesYes
    — Direct data exchange (slave-to-slave communication)Yes
    — DPV1Yes
    Address area
    — Inputs, max.2 kbyte
    — Outputs, max.2 kbyte
    User data per DP slave
    — User data per DP slave, max.244 byte
    — Inputs, max.244 byte
    — Outputs, max.244 byte
    — Slots, max.244
    — per slot, max.128 byte
    PROFIBUS DP slave
    ● Number of connections16
    ● GSD filehttp://support.automation.siemens.com/WW/view/en/113652
    ● Transmission rate, max.12 Mbit/s
    ● automatic baud rate searchNo
    ● Address area, max.32; Virtual slots
    ● User data per address area, max.32 byte
    — of which consistent, max.32 byte
    Services
    — PG/OP communicationYes; with interface active
    — RoutingYes; with interface active
    — Global data communicationNo
    — S7 basic communicationNo
    — S7 communicationYes
    — S7 communication, as clientYes
    — S7 communication, as serverYes
    — Direct data exchange (slave-to-slave communication)No
    — DPV1No
    Transfer memory
    — Inputs244 byte
    — Outputs244 byte
    Protocols
    Open IE communication
    ● ISO-on-TCP (RFC1006)Via CP 443-1 Adv. and loadable FB
    — Data length, max.1 452 bytes via CP 443-1 Adv.
    Web server
    ● supportedNo
    Isochronous mode
    EquidistanceYes
    Number of DP masters with isochronous mode1
    User data per isochronous slave, max.244 byte
    shortest clock pulse1.5 ms; 0.5 ms without use of SFC 126, 127
    max. cycle32 ms
    communication functions / header
    PG/OP communicationYes
    ● Number of connectable OPs without message processing31
    ● Number of connectable OPs with message processing31; When using Alarm_S/SQ and Alarm_D/DQ
    Data record routingYes
    Global data communication
    ● supportedYes
    ● Number of GD loops, max.8
    ● Number of GD packets, transmitter, max.8
    ● Number of GD packets, receiver, max.16
    ● Size of GD packets, max.54 byte
    ● Size of GD packet (of which consistent), max.1 variable
    S7 basic communication
    ● communication function / S7 basic communicationYes
    ● User data per job, max.76 byte
    ● User data per job (of which consistent), max.1 variable
    S7 communication
    ● supportedYes
    ● as serverYes
    ● as clientYes
    ● User data per job, max.64 kbyte
    ● User data per job (of which consistent), max.462 byte
    S5 compatible communication
    ● supportedYes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
    ● User data per job, max.8 kbyte
    ● User data per job (of which consistent), max.240 byte
    ● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.24/24
    Standard communication (FMS)
    ● supportedYes; Via CP and loadable FB
    Number of connections
    ● overall32
    ● usable for PG communication31
    — reserved for PG communication1
    — adjustable for PG communication, max.0
    ● usable for OP communication31
    — reserved for OP communication1
    — adjustable for OP communication, max.0
    ● usable for S7 basic communication30
    — reserved for S7 basic communication0
    — adjustable for S7 basic communication, max.0
    ● usable for S7 communication30
    — reserved for S7 communication0
    — adjustable for S7 communication, max.0
    ● usable for routing15
    — reserved for routing0
    — adjustable for routing, max.0
    S7 message functions
    Number of login stations for message functions, max.31; Max. 31 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm_8 and Alarm_P (e.g. WinCC)
    Symbol-related messagesYes
    SCAN procedureYes
    Program alarmsYes
    Process diagnostic messagesYes
    simultaneously active Alarm-S blocks, max.250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
    Alarm 8-blocksYes
    ● Number of instances for alarm 8 and S7 communication blocks, max.300
    ● preset, max.150
    Process control messagesYes
    Number of archives that can log on simultaneously (SFB 37 AR_SEND)4
    Number of messages
    ● overall, max.256
    ● in 100 ms grid, max.0
    ● in 500 ms grid, max.256
    ● in 1000 ms grid, max.256
    Number of additional values
    ● with 100 ms grid, max.0
    ● with 500, 1000 ms grid, max.1
    Test commissioning functions
    Status blockYes; Up to 2 simultaneously
    Single stepYes
    Number of breakpoints4
    Status/control
    ● Status/control variableYes; Up to 16 variable tables
    ● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
    ● Number of variables, max.70; Status/control
    Forcing
    ● ForcingYes
    ● Forcing, variablesInputs/outputs, bit memories, distributed I/Os
    ● Number of variables, max.64
    Diagnostic buffer
    ● presentYes
    ● Number of entries, max.200
    — adjustableYes
    — preset120
    Service data
    ● can be read outYes
    Standards, approvals, certificates
    CE markYes
    CSA approvalYes
    UL approvalYes
    cULusYes
    FM approvalYes
    RCM (formerly C-TICK)Yes
    KC approvalYes
    EAC (formerly Gost-R)Yes
    Use in hazardous areas
    ● ATEXATEX II 3G Ex nA IIC T4 Gc
    Ambient conditions
    Ambient temperature during operation
    ● min.0 °C
    ● max.60 °C
    configuration / header
    Configuration software
    ● STEP 7Yes
    configuration / programming / header
    ● Command setsee instruction list
    ● Nesting levels7
    ● Access to consistent data in process imageYes
    ● System functions (SFC)see instruction list
    ● System function blocks (SFB)see instruction list
    Programming language
    — LADYes
    — FBDYes
    — STLYes
    — SCLYes
    — CFCYes
    — GRAPHYes
    — HiGraph®Yes
    configuration / programming / number of simultaneously active SFC / header
    — DPSYC_FR2; SFC 11; per interface
    — D_ACT_DP8; SFC 12; per interface
    — RD_REC8; SFC 59; per interface
    — WR_REC8; SFC 58; per interface
    — WR_PARM8; SFC 55; per interface
    — PARM_MOD1; SFC 57; per interface
    — WR_DPARM2; SFC 56; per interface
    — DPNRM_DG8; SFC 13; per interface
    — RDSYSST8; SFC 51
    — DP_TOPOL1; SFC 103; per interface
    configuration / programming / number of simultaneously active SFB / header
    — RDREC8; SFB 52; per interface, but not more than 32 across all external interfaces
    — WRREC8; SFB 53; per interface, but not more than 32 across all external interfaces
    Know-how protection
    ● User program protection/password protectionYes
    Dimensions
    Width25 mm
    Height290 mm
    Depth219 mm
    Weights
    Weight, approx.700 g