Sign In | Join Free | My himfr.com
Home > PLC SIMATIC S7-1500 >

SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA

    Buy cheap SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA from wholesalers
     
    Buy cheap SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA from wholesalers
    • Buy cheap SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA from wholesalers

    SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA

    Ask Lasest Price
    Brand Name : SIEMENS
    Model Number : 6ES7515-2AM01-0AB0
    Certification : CE
    Price : USD
    Payment Terms : L/C, T/T
    Supply Ability : 100
    Delivery Time : 10-12Days
    • Product Details
    • Company Profile

    SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA

    SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA

    The SIEMENS 6ES7515-2AM01-0AB0 is a central processing unit (CPU) that is part of the SIMATIC S7-1500 automation system. Some key features of this CPU include:


    • Work Memory: 500 KB for program storage and 3 MB for data storage

    • This provides ample memory capacity for program code and data processing in automation applications.

    • CPU Type: The CPU is based on a high-performance processor that can execute program logic and control industrial processes efficiently.

    • Interfaces: The CPU has integrated interfaces such as PROFINET for communication with other devices on an industrial network.

    • Scalability: The CPU is part of the modular SIMATIC S7-1500 system, allowing it to be easily integrated into larger automation solutions.

    • Safety Features: The CPU supports functional safety capabilities for applications that require enhanced protection.

    • Programming: It can be programmed using the STEP 7 engineering software from Siemens, providing a comprehensive automation programming environment.

    General information
    Product type designationCPU 1515-2 PN
    HW functional statusFS03
    Firmware versionV2.9
    Product function
    ● I&M dataYes; I&M0 to I&M3
    ● Isochronous modeYes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central)
    Engineering with
    ● STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V13 (FW V1.5) or higher
    Configuration control
    via datasetYes
    Display
    Screen diagonal [cm]6.1 cm
    Control elements
    Number of keys6
    Mode selector switch1
    Supply voltage
    Rated value (DC)24 V
    permissible range, lower limit (DC)19.2 V
    permissible range, upper limit (DC)28.8 V
    Reverse polarity protectionYes
    Mains buffering
    ● Mains/voltage failure stored energy time5 ms
    Input current
    Current consumption (rated value)0.8 A
    Inrush current, max.2.4 A; Rated value
    I²t0.02 A²·s
    Power
    Infeed power to the backplane bus12 W
    Power consumption from the backplane bus (balanced)6.2 W
    Power loss
    Power loss, typ.6.3 W
    Memory
    Number of slots for SIMATIC memory card1
    SIMATIC memory card requiredYes
    Work memory
    ● integrated (for program)500 kbyte
    ● integrated (for data)3 Mbyte
    Load memory
    ● Plug-in (SIMATIC Memory Card), max.32 Gbyte
    Backup
    ● maintenance-freeYes
    CPU processing times
    for bit operations, typ.30 ns
    for word operations, typ.36 ns
    for fixed point arithmetic, typ.48 ns
    for floating point arithmetic, typ.192 ns
    CPU-blocks
    Number of elements (total)8 000; Blocks (OB, FB, FC, DB) and UDTs
    DB
    ● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
    ● Size, max.3 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
    FB
    ● Number range0 ... 65 535
    ● Size, max.500 kbyte
    FC
    ● Number range0 ... 65 535
    ● Size, max.500 kbyte
    OB
    ● Size, max.500 kbyte
    ● Number of free cycle OBs100
    ● Number of time alarm OBs20
    ● Number of delay alarm OBs20
    ● Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
    ● Number of process alarm OBs50
    ● Number of DPV1 alarm OBs3
    ● Number of isochronous mode OBs2
    ● Number of technology synchronous alarm OBs2
    ● Number of startup OBs100
    ● Number of asynchronous error OBs4
    ● Number of synchronous error OBs2
    ● Number of diagnostic alarm OBs1
    Nesting depth
    ● per priority class24
    Counters, timers and their retentivity
    S7 counter
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC counter
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    S7 times
    ● Number2 048
    Retentivity
    — adjustableYes
    IEC timer
    ● NumberAny (only limited by the main memory)
    Retentivity
    — adjustableYes
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max.512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
    Extended retentive data area (incl. timers, counters, flags), max.3 Mbyte; When using PS 6 0W 24/48/60 V DC HF
    Flag
    ● Size, max.16 kbyte
    ● Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
    Data blocks
    ● Retentivity adjustableYes
    ● Retentivity presetNo
    Local data
    ● per priority class, max.64 kbyte; max. 16 KB per block
    Address area
    Number of IO modules8 192; max. number of modules / submodules
    I/O address area
    ● Inputs32 kbyte; All inputs are in the process image
    ● Outputs32 kbyte; All outputs are in the process image
    per integrated IO subsystem
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    per CM/CP
    — Inputs (volume)8 kbyte
    — Outputs (volume)8 kbyte
    Subprocess images
    ● Number of subprocess images, max.32
    Hardware configuration
    Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
    Number of DP masters
    ● Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
    Number of IO Controllers
    ● integrated2
    ● Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
    Rack
    ● Modules per rack, max.32; CPU + 31 modules
    PtP CM
    ● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
    Time of day
    Clock
    ● TypeHardware clock
    ● Backup time6 wk; At 40 °C ambient temperature, typically
    ● Deviation per day, max.10 s; Typ.: 2 s
    Operating hours counter
    ● Number16
    Clock synchronization
    ● supportedYes
    ● in AS, masterYes
    ● in AS, slaveYes
    ● on Ethernet via NTPYes
    Interfaces
    Number of PROFINET interfaces2
    1. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X1
    ● Number of ports2
    ● integrated switchYes
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyYes
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeYes
    — Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
    — IRTYes
    — PROFIenergyYes; per user program
    — Prioritized startupYes; Max. 32 PROFINET devices
    — Number of connectable IO Devices, max.256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Of which IO devices with IRT, max.64
    — Number of connectable IO Devices for RT, max.256
    — of which in line, max.256
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for IRT
    — for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
    — for send cycle of 500 µs500 µs to 8 ms
    — for send cycle of 1 ms1 ms to 16 ms
    — for send cycle of 2 ms2 ms to 32 ms
    — for send cycle of 4 ms4 ms to 64 ms
    — With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
    Update time for RT
    — for send cycle of 250 µs250 µs to 128 ms
    — for send cycle of 500 µs500 µs to 256 ms
    — for send cycle of 1 ms1 ms to 512 ms
    — for send cycle of 2 ms2 ms to 512 ms
    — for send cycle of 4 ms4 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTYes
    — PROFIenergyYes; per user program
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — activation/deactivation of I-devicesYes; per user program
    — Asset management recordYes; per user program
    2. Interface
    Interface types
    ● RJ 45 (Ethernet)Yes; X2
    ● Number of ports1
    ● integrated switchNo
    Protocols
    ● IP protocolYes; IPv4
    ● PROFINET IO ControllerYes
    ● PROFINET IO DeviceYes
    ● SIMATIC communicationYes
    ● Open IE communicationYes; Optionally also encrypted
    ● Web serverYes
    ● Media redundancyNo
    PROFINET IO Controller
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — Direct data exchangeNo
    — IRTNo
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Number of connectable IO Devices, max.32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
    — Number of connectable IO Devices for RT, max.32
    — of which in line, max.32
    — Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
    — Number of IO Devices per tool, max.8
    — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
    Update time for RT
    — for send cycle of 1 ms1 ms to 512 ms
    PROFINET IO Device
    Services
    — PG/OP communicationYes
    — Isochronous modeNo
    — IRTNo
    — PROFIenergyYes; per user program
    — Prioritized startupNo
    — Shared deviceYes
    — Number of IO Controllers with shared device, max.4
    — activation/deactivation of I-devicesYes; per user program
    — Asset management recordYes; per user program
    Interface types
    RJ 45 (Ethernet)
    ● 100 MbpsYes
    ● AutonegotiationYes
    ● AutocrossingYes
    ● Industrial Ethernet status LEDYes
    Protocols
    PROFIsafeNo
    Number of connections
    ● Number of connections, max.192; via integrated interfaces of the CPU and connected CPs / CMs
    ● Number of connections reserved for ES/HMI/web10
    ● Number of connections via integrated interfaces108
    ● Number of S7 routing paths16
    Redundancy mode
    ● H-Sync forwardingYes
    Media redundancy
    — Media redundancyonly via 1st interface (X1)
    — MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
    — MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
    — MRPDYes; Requirement: IRT
    — Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
    — Number of stations in the ring, max.50
    SIMATIC communication
    ● PG/OP communicationYes; encryption with TLS V1.3 pre-selected
    ● S7 routingYes
    ● S7 communication, as serverYes
    ● S7 communication, as clientYes
    ● User data per job, max.See online help (S7 communication, user data size)
    Open IE communication
    ● TCP/IPYes
    — Data length, max.64 kbyte
    — several passive connections per port, supportedYes
    ● ISO-on-TCP (RFC1006)Yes
    — Data length, max.64 kbyte
    ● UDPYes
    — Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
    — UDP multicastYes; Max. 5 multicast circuits
    ● DHCPYes
    ● DNSYes
    ● SNMPYes
    ● DCPYes
    ● LLDPYes
    ● EncryptionYes; Optional
    Web server
    ● HTTPYes; Standard and user pages
    ● HTTPSYes; Standard and user pages
    OPC UA
    ● Runtime license requiredYes; "Medium" license required
    ● OPC UA ClientYes
    — Application authenticationYes
    — Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
    — User authentication"anonymous" or by user name & password
    — Number of connections, max.10
    — Number of nodes of the client interfaces, recommended max.2 000
    — Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
    — Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
    — Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
    — Number of simultaneous calls of the client instructions for session management, per connection, max.1
    — Number of simultaneous calls of the client instructions for data access, per connection, max.5
    — Number of registerable nodes, max.5 000
    — Number of registerable method calls of OPC_UA_MethodCall, max.100
    — Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
    ● OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
    — Application authenticationYes
    — Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
    — User authentication"anonymous" or by user name & password
    — GDS support (certificate management)Yes
    — Number of sessions, max.48
    — Number of accessible variables, max.100 000
    — Number of registerable nodes, max.20 000
    — Number of subscriptions per session, max.20
    — Sampling interval, min.100 ms
    — Publishing interval, min.200 ms
    — Number of server methods, max.50
    — Number of inputs/outputs per server method, max.20
    — Number of monitored items, recommended max.2 000; for 1 s sampling interval and 1 s send interval
    — Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
    — Number of nodes for user-defined server interfaces, max.5 000
    ● Alarms and ConditionsYes
    — Number of program alarms200
    — Number of alarms for system diagnostics100
    Further protocols
    ● MODBUSYes; MODBUS TCP
    S7 message functions
    Number of login stations for message functions, max.64
    Program alarmsYes
    Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
    Number of loadable program messages in RUN, max.5 000
    Number of simultaneously active program alarms
    ● Number of program alarms800
    ● Number of alarms for system diagnostics200
    ● Number of alarms for motion technology objects160
    Test commissioning functions
    Joint commission (Team Engineering)Yes; Parallel online access possible for up to 8 engineering systems
    Status blockYes; Up to 8 simultaneously (in total across all ES clients)
    Single stepNo
    Number of breakpoints8
    Status/control
    ● Status/control variableYes
    ● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
    ● Number of variables, max.
    — of which status variables, max.200; per job
    — of which control variables, max.200; per job
    Forcing

    SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA

    Quality SIEMENS 6ES7515-2AM01-0AB0 ENTRAL PROCESSING UNIT WITH WORK MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Voboal Industrial Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)